Defined in 1 files as a function:

Referenced in 1 files:

Smatch caller information:

drivers/iio/pressure/rohm-bm1390.c bm1390_fifo_disable() -> bm1390_meas_set()

Type Parameter Key Value
PARAM_VALUE 1 mode 0
RX_PATH
TASK_NOT_RUNNING
LOCK2 _T->lock

drivers/iio/pressure/rohm-bm1390.c bm1390_fifo_enable() -> bm1390_meas_set()

Type Parameter Key Value
PARAM_VALUE 0 data 4096-ptr_max
PARAM_VALUE 0 data->irq 1-s32max
PARAM_VALUE 0 data->regmap 4096-ptr_max
PARAM_VALUE 0 data->regmap->async 0
PARAM_VALUE 0 data->regmap->cache_dirty 1
PARAM_VALUE 0 data->state 1
PARAM_VALUE 0 data->trigger_enabled 0
PARAM_VALUE 1 mode 2
CAPPED_DATA 0 data->regmap->precious_table->n_no_ranges 1
CAPPED_DATA 0 data->regmap->rd_table->n_no_ranges 1
CAPPED_DATA 0 data->regmap->rd_table->n_yes_ranges 1
CAPPED_DATA 0 data->regmap->volatile_table->n_no_ranges 1
CAPPED_DATA 0 data->regmap->volatile_table->n_yes_ranges 1
CAPPED_DATA 0 data->regmap->wr_table->n_no_ranges 1
CAPPED_DATA 0 data->regmap->wr_table->n_yes_ranges 1
FUZZY_MAX 0 data->irq 1
RX_PATH
TASK_NOT_RUNNING
LOCK2 _T->lock
HALF_LOCKED2 &of->mutex

drivers/iio/pressure/rohm-bm1390.c bm1390_read_data() -> bm1390_meas_set()

Type Parameter Key Value
PARAM_VALUE 1 mode 2
DATA_SOURCE 0 data $0
RX_PATH
TASK_NOT_RUNNING
LOCK2 _T->lock
HALF_LOCKED2 &of->mutex

drivers/iio/pressure/rohm-bm1390.c bm1390_read_data() -> bm1390_meas_set()

Type Parameter Key Value
PARAM_VALUE 0 data 4096-ptr_max
PARAM_VALUE 0 data->regmap 4096-ptr_max
PARAM_VALUE 0 data->regmap->async 0
PARAM_VALUE 0 data->regmap->cache_dirty 0-1
PARAM_VALUE 1 mode 0
CAPPED_DATA 0 data->regmap->precious_table->n_no_ranges 1
CAPPED_DATA 0 data->regmap->rd_table->n_no_ranges 1
CAPPED_DATA 0 data->regmap->rd_table->n_yes_ranges 1
CAPPED_DATA 0 data->regmap->volatile_table->n_no_ranges 1
CAPPED_DATA 0 data->regmap->volatile_table->n_yes_ranges 1
CAPPED_DATA 0 data->regmap->wr_table->n_no_ranges 1
CAPPED_DATA 0 data->regmap->wr_table->n_yes_ranges 1
DATA_SOURCE 0 data $0
RX_PATH
TASK_NOT_RUNNING
LOCK2 _T->lock
HALF_LOCKED2 &of->mutex

drivers/iio/pressure/rohm-bm1390.c bm1390_trigger_set_state() -> bm1390_meas_set()

Type Parameter Key Value
PARAM_VALUE 0 data 4096-ptr_max
PARAM_VALUE 0 data->state 0,2-u32max
PARAM_VALUE 0 data->trigger_enabled 1
PARAM_VALUE 1 mode 2
BUF_SIZE 0 data s32min-(-2),1-s32max
BUF_SIZE 0 data s32min-(-2),1-s32max
RX_PATH
TASK_NOT_RUNNING
UNITS 0 data unit_byte
LOCK2 _T->lock
HALF_LOCKED2 &of->mutex

drivers/iio/pressure/rohm-bm1390.c bm1390_trigger_set_state() -> bm1390_meas_set()

Type Parameter Key Value
PARAM_VALUE 0 data 4096-ptr_max
PARAM_VALUE 0 data->state 0,2-u32max
PARAM_VALUE 0 data->trigger_enabled 0
PARAM_VALUE 1 mode 0
BUF_SIZE 0 data s32min-(-2),1-s32max
BUF_SIZE 0 data s32min-(-2),1-s32max
RX_PATH
TASK_NOT_RUNNING
UNITS 0 data unit_byte
LOCK2 _T->lock
HALF_LOCKED2 &of->mutex